Product Overview
A high temperature thermocouple protection tube shields the thermocouple wires from oxidation, corrosion, and mechanical damage at the measurement point, without interfering with the temperature signal. It is used in industrial furnaces, glass melting furnaces, metallurgical furnaces, and laboratory and atmosphere furnaces.
The Two Failure Modes Buyers Ask About
Signal interference. The tube material has to be electrically non-conductive and non-magnetic so it does not affect the thermocouple signal. Alumina is both. Volume resistivity is above 10¹⁴ Ω·cm, and it holds at high temperature rather than only at ambient.
Thermal shock cracking. Pulling a tube out of a hot furnace or inserting it into one causes a rapid temperature change, and that is what cracks ceramic tubes. The grain size and glass phase distribution are controlled to improve thermal shock resistance. The tube withstands a temperature differential of 200°C or more without cracking.
|
Item |
Value |
|
Material |
99% alumina |
|
Maximum operating temperature |
1700°C |
|
Thermal shock resistance |
ΔT ≥ 200°C |
|
Volume resistivity |
> 10¹⁴ Ω·cm |
|
Outer diameter |
5–50 mm |
|
Inner diameter |
3–40 mm |
|
Length |
50–1000 mm |
|
Structure |
Blind tube / open tube (per requirement) |
Chemical Compatibility
High-purity alumina is chemically inert in oxidizing and neutral atmospheres and does not react with common thermocouple materials such as Type K, Type S, and Type B. In a strongly reducing atmosphere or in the presence of specific metal vapors, compatibility should be assessed before the tube is specified. This is stated because it is the one condition where the material choice can change.
Blind Tube or Open Tube
A blind tube protects the measurement end and is used where the thermocouple has to be isolated from the medium being measured. An open tube is used where fast response or insert-style mounting is required. The choice is made against the thermocouple type and the mounting method.
Applications
Thermocouple protection in industrial furnaces
01
Temperature measurement protection in glass melting furnaces
02
High-temperature measurement in metallurgical furnaces
03
Thermocouple protection in laboratory and atmosphere furnaces
04
FAQ
Q: Will the tube react with the thermocouple wires at high temperature?
A: High-purity alumina is chemically inert in oxidizing and neutral atmospheres and does not react with common thermocouple materials such as Type K, Type S, and Type B. In a strongly reducing atmosphere or in the presence of specific metal vapors, a compatibility assessment is recommended before the tube is specified.
Q: How do I choose between a blind tube and an open tube?
A: A blind tube is used where the measurement end has to be isolated from the medium. An open tube is used where fast response or insert-style mounting is required. The choice depends on the thermocouple type and the mounting method.
Hot Tags: high temperature thermocouple protection tube, China high temperature thermocouple protection tube manufacturers, suppliers, factory, Alumina Ceramic Tube, Alumina Tube, ceramic tube, High Temperature Ceramic Tube